The Model CAC Air Curtain

 

ADS-400

The Model CAC Air Curtain is for applications where temperatures and humidity exceed the limits of our Model AC. A heater unit is added to condition the air as it mixes inside the vestibule.

The Model CAC automatically adjusts as conditions change to optimize performance and reduce energy consumption.

With the use of HCR sensors and software, Model CAC can be integrated into a facility's refrigeration control and monitoring system.  This allows not only remote monitoring but remote adjusting of the HCR equipment.

  • The Model CAC Air Curtain
  • Using Computational Fluid Dynamic software, air flow patterns with HCR’s Air Curtain are made visible. CFD software shows how the air is circulating and captured within the AC unit
The Model CAC Air Curtain Using Computational Fluid Dynamic software, air flow patterns with HCR’s Air Curtain are made visible. CFD software shows how the air is circulating and captured within the AC unit

Features

  • Single Nozzle And Intake
  • Proprietary Nozzle Design
  • Greatly Diminishes Air and Moisture Infiltration
  • Horizontal, Curvilinear,Recirculatory Air Flow
  • Powder Coated Steel
  • Metal Clad Insulation When Required
 
  • Specifications

    Cooler or Ambient Door Specifications

    Supply where indicated on plans HCR Model AC Air Door for doorways with low temperature differential and or for temperatures above freezing.
     
    Air Door to be powder coated cold-rolled steel. Powder coating meets 500 hour salt spray test.
     
    NEMA 1 Power/control panel complete. Model AC equipment cabinet houses the centrifugal fan and prewired electrical components. Service door(s) are provided, if required, to allow access to all internal components. Motor is controlled by VFD (Variable Frequency Drive). Single point electrical connection.
     
    Air Door to have two side plenums: one with discharge nozzle, the other with an intake.
     
    Discharge nozzle is easily adjustable to maximize air block. Air volume adjustment mechanisms are easily accessible without removing any covers or secondary openings.
     
    Unit can be mounted on either side of wall. Depending on temperature differential, insulation cladding may be required.
    Air Door assembly is structurally self-supporting. All hardware has protective coating against corrosion.
     
    Air Door power to be 208, 240, or 480 volt AC, 60 Hertz, 3 phase. Visible signal light to show when motor is not running. Complete door assembly to be ready for connection to power. (Architect to designate responsibility for field wiring.)
     

    Freezer Door Specifications:

    Freezer Air Door specifications to be same as cooler or ambient Air Door except for these substitutions and additions: Supply where indicated on plans HCR Model CAC for freezers doorways with temperature differentials below 30 degrees Fahrenheit. Provide insulation cladding as required for application.
     
    Cabinet can be mounted either warm side or cold side of wall.
     
    Electric resistive heat or waste heat reclaim as required.
    Architectural Data Sheets
  • Options & Accessories
    1. Metal cladding can be stainless steel or cold-rolled steel powder coated to custom color.
    2. "Clean outs" can be added where needed.
    3. Complete NEMA 3, 4, 4x, 4x stainless, or 12 requirements.
    4. Hot Gas Coil instead of resistive heat.
    5. Custom standoff panels with trim to interconnect to night doors or existing doors.
    6. HCR Air Door to be used in conjunction with existing or new door to form a Hybrid solution. These doors can include all types of insulated roll up doors, double curtain roll up doors, hard insulated automatic doors that slide either horizontally or vertically, or insulated sliding mattress doors. If a non-insulated door is used verify condensation or frosting can occur.